Indoor Fiber Optic Cables [DT-NVSKZXX]

  • Fiber Optic Cable
  • Loose Tube / Dry Cored / Single-Armored / Single Jacket PE
  • Color coded optical fibers, jelly filled color coded loose tubes, PE filler (if necessary), water blocking yarn around central strength member, SZ-stranded around the dielectric central strength member, core wrapping tape, outer strength member if necessary, water blocking tape if necessary, ripcord, corrugated steel tape armor and outer PE jacket

See below for specifications.

Inquiries/Quotations? Email us at: [email protected]

Or Call/Text: +63-9209091854

Central Loose Tube Single Armored / Single Jacket [ DT-NVSKZXX]

Cable Part Number
24 Core OM4 DT-NVSKZXX/BRXMX24X
4 Core SM DT-NVSKZXX/ARXSE4XX
12 Core SM DT-NVSKZXX/ARXSE12X
ITEMS TEST METHOD AND
ACCEPTANCE CRITERIA
Tensile Loading
And Bending Test
# Test method: TIA/EIA-455-33A
-. Mandrel diameter: 30D (D = cable diameter)
-. Installation tensile load: 1,600N for 1 hour
-. Residual tensile load: 800N for 10 minutes
# Acceptance Criteria
-. Fiber strain: ≤ 0.6 for installation tensile load
-. Attenuation increment: ≤ 0.10 dB/km (SMF)
≤ 0.20 dB/km (MMF)
for residual tensile load
Compressive Loading
Resistance Test
# Test method: TIA/EIA-455-41A
-. Short term load: 3000 N/10cm for 1 minute
-. Long term load: 1100 N/10cm for 10 minutes
# Acceptance Criteria
-. Attenuation increment: ≤ 0.10 dB/km (SMF)
≤ 0.20 dB/km (MMF)
after completion of the test
-. No jacket cracking and fiber breakage
Repeated Impact Test # Test method: TIA/EIA-455-25C
-. Height of impact: 150mm
-. Impacting mass: 3kg
-. No. of impact cycles: 2 cycles at 3 different points
# Acceptance Criteria
-. Attenuation increment: ≤ 0.10 dB/km (SMF)
≤ 0.20 dB/km (MMF)
after completion of the test
-. No jacket cracking and fiber breakage
Items Description
Number of Fibers Max. 24
Loose Buffer Tube PBT (Polybutylene Terephthalate)
Filling Compound in Loose Buffer Tube Thixotropic Jelly Compound
Water Blocking Material Water Swellable Tape (over Loose Tube)
Armor Material Corrugated Steel Tape with Plastic Coating
Armor Thickness Nom 0.15mm (Steel Tape)

Nom 0.05 (Plastic Coating on Both Sides)

Sheath Strength Member Two Steel Wires
Outer Jacket Material Black PE or Black LSZH
Outer Jacket Thickness Nom. 2.1mm

 

Cyclic Flexing Test # Test method: TIA/EIA-455-104A
-. Sheave diameter: 20D (D = cable diameter)
-. No. of flexing cycles: 25 cycles
-. Flexing speed: 30 cycles/minute
# Acceptance Criteria
-. Attenuation increment: ≤ 0.10 dB/km (SMF)
≤ 0.20 dB/km (MMF)
after completion of the test
-. No jacket cracking and fiber breakage
Cable Twist Test # Test method: TIA/EIA-455-85A
-. Cable length twisted: 2m
-. No. of twist cycles: 10 cycles
-. Twist angle: ±180°
# Acceptance Criteria
-. Attenuation increment: ≤ 0.10 dB/km (SMF)
≤ 0.20 dB/km (MMF)
after completion of the test
-. No jacket cracking and fiber breakage
Temperature Cycling Test # Test method: TIA/EIA-455-3A
-. Temperature cycling schedule
: 23°C → -20°C → 70°C → -20°C → 70°C → 23°C
-. Soak time at each temperature: 8hours
# Acceptance Criteria
-. Attenuation increment: ≤ 0.15 dB/km (SMF)
≤ 0.30 dB/km (MMF)
Water Penetration Test # Test method: TIA/EIA-455-82B
-. Length of specimen: 3m
-. Height of pressure head: 1m
-. Test time: 24 hours
# Acceptance Criteria
-. No leakage through the open cable end
Flammability Test
(LSZH Jacket Cable only)
# Test method and Acceptance Criteria
The cable shall comply with IEC 332-1.

Click here for Spec Sheet: [LSSS-OC0072-04]_Distribution Fiber Cable

For More Info and Product Specifications, Please Visit the LS Cable Website:

http://lssimple.com/en/product/category3.asp?cate1=202&cate2=230&cate3=236

Inquiries/Quotations? Email us at: [email protected]

Or Call: +63-9209091854